BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:GEANT4 Simulation of a Portable Scintillator-Cube/GEM Detector for
  Cosmic-Ray Muography
DTSTART;VALUE=DATE-TIME:20261203T210000Z
DTEND;VALUE=DATE-TIME:20261203T213000Z
DTSTAMP;VALUE=DATE-TIME:20261123T191707Z
UID:indico-contribution-404@fisindico.uniandes.edu.co
DESCRIPTION:Speakers: Alex Tapia (Universidad de Medellín)\nWe present th
 e design and GEANT4 Monte Carlo characterization\nof a portable\, modular 
 cosmic-ray muon telescope intended for\nsmall-to-medium-scale muography ap
 plications. The instrument combines\na segmented plastic-scintillator cube
 \, arranged as an $N\\times N\\times N$\narray of individually wrapped cel
 ls (default $N=3$\, $50\\times50\\times50$\ncm$^3$)\, with a single Gas El
 ectron Multiplier (GEM) tracking plane\nmounted below it at a variable sta
 nd-off distance. The full assembly is\nmounted on a mechanically realistic
  aluminium support structure --\ncorner posts\, a GEM-holder frame and a b
 ase plate -- that in turn\npivots\, about a fixed floor stand\, through an
  adjustable zenith angle\,\nso that the instrument's line of sight can be 
 swept from the local\nzenith to near-horizontal. We describe the GEANT4 im
 plementation\nof the geometry\, materials and physics\, the cosmic-ray pri
 mary\ngenerator\, and the ROOT-based data output used for per-hit\ntrack r
 econstruction. We then present a feasibility study for using the\ninstrume
 nt in a muography configuration: a fixed\, vertically-standing\ntarget of 
 standard rock (Particle Data Group definition\, $\\rho=2.65$\ng/cm$^3$)\, 
 sized to a Tusa-natural-pyramid-like scale $230$ m base\,\n$140$ m height\
 , $400$ m stand-off)\, is introduced along the\ntelescope's line of sight\
 , and the muon transmission through it is\nobtained by comparing paired op
 en-sky and with-target runs at matched\nzenith angles. We discuss the geom
 etrical and event-generation\nmethodology required for this comparison to 
 be physically meaningful\,\ngive analytic cross-checks of the expected roc
 k path length and the\nminimum surface muon energy needed to traverse it a
 s a function of\nzenith angle\, and outline the full-statistics Monte Carl
 o campaign\nneeded to obtain a quantitative transmission curve.\n\nhttps:/
 /fisindico.uniandes.edu.co/event/18/contributions/404/
LOCATION:Universidad de los Andes SD-803
URL:https://fisindico.uniandes.edu.co/event/18/contributions/404/
END:VEVENT
END:VCALENDAR