BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//CERN//INDICO//EN
BEGIN:VEVENT
SUMMARY:Tracking and Timing Performance of a Muon Hodoscope for Transmissi
 on Muography
DTSTART;VALUE=DATE-TIME:20261203T203000Z
DTEND;VALUE=DATE-TIME:20261203T205000Z
DTSTAMP;VALUE=DATE-TIME:20261123T184633Z
UID:indico-contribution-449@fisindico.uniandes.edu.co
DESCRIPTION:Speakers: Juan José Guzmán Mejía (Universidad de los Andes)
 \nWe present the tracking and timing performance characterization of a pla
 stic scintillator muon hodoscope developed at Universidad de los Andes for
  transmission and scattering muography. In this work\, we focus on the per
 formance relevant to transmission muography. The hodoscope comprises four 
 tracking matrices with an active area of $57\\times57~\\mathrm{cm^2}$\, us
 ing triangular scintillator bars coupled to wavelength shifting fibers and
  silicon photomultipliers\, together with two external scintillator plates
  read out by photomultiplier tubes. The two plates define the event trigge
 r through a coincidence implemented with NIM electronics\, while CAMAC TDC
  and QDC modules provide independent timing and charge measurements. The f
 our CAEN FERS 5200 boards provide synchronized spectroscopic and timing in
 formation from the tracking matrices. Charge centroid reconstruction using
  the four matrices yields spatial resolution estimators of approximately 2
 .6-3.0 mm and angular resolution estimators of 0.12-0.14$^\\circ$. In a co
 nfiguration with the detector axis horizontal\, the external plates were s
 eparated by 1.91 m and the timing difference between the plates resolves t
 wo populations associated with opposite muon propagation directions\, with
  a separation of 13.07 ns. After excluding a background component\, the tw
 o directional populations exhibit Gaussian widths of 1.81 ns and 2.01 ns. 
 Complementary measurements with the CAEN system in the vertical detector c
 onfiguration yield a plate timing difference width of approximately 1.89 n
 s and pairwise matrix timing widths of 1.34-2.29 ns. This directional sens
 itivity is particularly relevant for the proposed transmission measurement
 s\, where the detector will operate approximately horizontally so that its
  angular acceptance simultaneously covers open sky and a geological struct
 ure. This configuration allows the open sky reference and transmitted muon
  populations to be recorded during the same acquisition\, while timing inf
 ormation determines the propagation direction of reconstructed tracks and 
 contributes to background discrimination.\n\nhttps://fisindico.uniandes.ed
 u.co/event/18/contributions/449/
LOCATION:Universidad de los Andes SD-804
URL:https://fisindico.uniandes.edu.co/event/18/contributions/449/
END:VEVENT
END:VCALENDAR
