GEANT4 Simulation of a Portable Scintillator-Cube/GEM Detector for Cosmic-Ray Muography

3 Dec 2026, 16:00
30m
SD-803 (Universidad de los Andes)

SD-803

Universidad de los Andes

Parallel Talk Detector Applications and Computational Methods Parallel Talks-SD:803

Speaker

Alex Tapia (Universidad de Medellín)

Description

We present the design and GEANT4 Monte Carlo characterization
of a portable, modular cosmic-ray muon telescope intended for
small-to-medium-scale muography applications. The instrument combines
a segmented plastic-scintillator cube, arranged as an $N\times N\times N$
array of individually wrapped cells (default $N=3$, $50\times50\times50$
cm$^3$), with a single Gas Electron Multiplier (GEM) tracking plane
mounted below it at a variable stand-off distance. The full assembly is
mounted on a mechanically realistic aluminium support structure --
corner posts, a GEM-holder frame and a base plate -- that in turn
pivots, about a fixed floor stand, through an adjustable zenith angle,
so that the instrument's line of sight can be swept from the local
zenith to near-horizontal. We describe the GEANT4 implementation
of the geometry, materials and physics, the cosmic-ray primary
generator, and the ROOT-based data output used for per-hit
track reconstruction. We then present a feasibility study for using the
instrument in a muography configuration: a fixed, vertically-standing
target of standard rock (Particle Data Group definition, $\rho=2.65$
g/cm$^3$), sized to a Tusa-natural-pyramid-like scale $230$ m base,
$140$ m height, $400$ m stand-off), is introduced along the
telescope's line of sight, and the muon transmission through it is
obtained by comparing paired open-sky and with-target runs at matched
zenith angles. We discuss the geometrical and event-generation
methodology required for this comparison to be physically meaningful,
give analytic cross-checks of the expected rock path length and the
minimum surface muon energy needed to traverse it as a function of
zenith angle, and outline the full-statistics Monte Carlo campaign
needed to obtain a quantitative transmission curve.

Academic position of the presenting author Professor

Primary author

Alex Tapia (Universidad de Medellín)

Co-author

Mr Julián Díaz (Universidad EAFIT)

Presentation Materials

There are no materials yet.